Plot of the Temperature Distribution

We now plot the temperature distribution described by Equation (3.16) for a = 5.224 x 10-11 ohm, m/K, b = 1.724 x10-8 ohm, m, I = 100 amps, k = 401 W/mK , Ac = D2, D = 10mm, T0 = 293 K, TL = 373 K, L = 1m.

Figure 3

Copyright 1998-2001 Rensselaer Polytechnic Institute. All Rights Reserved.