1 LA120 LA120 Operator Reference Card The following help is available for LA120's COMMUNICATION - Communications proto-call SET-UP commands BAUD - BAUD rate SET-UP FORMS - Forms control SET-UP commands HORIZONTAL - Setting horizontal pitch (characters per inch) MODEM - Modem control SET-UP OPERATOR - Operator convenience SET-UP commands PARITY - Parity and number of data bits SET-UP RECALL - Re-calling last saved SET-UP SETUP - How to enter SET-UP mode SPLIT - Split BAUD rate SET-UP STATUS - Displaying current SET-UP STORE - Saving SET-UP TEST - Self test VERTICAL - Setting vertical pitch (lines per inch) 2 SETUP SET-UP: Key Function/Comments --------------- ----------------------------------- CTRL and SET-UP Locks LA120 in set-up mode: SET-UP light flashes. To exit set-up mode press SET-UP. SET-UP Places LA120 in set-up mode while SET-UP is held down; SET-UP light flashes. To exit set-up mode release SET-UP. 2 FORMS Forms: Key Function/Comments -------------------- --------------------------------------- SHIFT Display current line number, releasing SHIFT returns display to current column number. 1 Set horizontal tab at current column. SHIFT 1 Set vertical tab at current line. 2 Clear horizontal tab at current column. SHIFT 2 Clear vertical tab at current line. 3 Clear all horizontal tabs. SHIFT 3 Clear all vertical tabs. SHIFT 4 Establish top of form (TOF). 4 Establish top of form (TOF). 5 Set minimum column number (left margin). SHIFT 5 Set minimum line number (top margin). 6 Set maximum column number (right margin). SHIFT 6 Set maximum line number (bottom margin). 7 Clear left and right margins. SHIFT 7 Clear top and bottom margins. F Form Length, displays 1 thru 168, clears top and bottom margins and establishes TOF. 2 HORIZONTAL Horizontal Pitch: Key Function/Comments ----------- --------------------------------------- H Horizontal pitch (Characters per inch). NOTE: Changing horizontal pitch clears left and right margins. DISPLAY PITCH 5 5.00 CPI 6 6.00 CPI 7 6.60 CPI 8 8.25 CPI 10 10.0 CPI 12 12.0 CPI 13 13.2 CPI 16 16.5 CPI 2 VERTICAL Vertical Pitch: Key Function/Comments ----------- --------------------------------------- V Vertical pitch (Lines per inch). NOTE: Changing vertical pitch clears top and bottom margins. DISPLAY PITCH 2 2 LPI 3 3 LPI 4 4 LPI 6 6 LPI 8 8 LPI 12 12 LPI 2 OPERATOR Operator Comfort: Key Function/Comments --- ----------------- G Bell volume 0 = Low Volume 1 = High Volume K Key click 0 = Off 1 = On R Auto repeat 0 = Off 1 = On Z Last character view 0 = Manual 1 = Auto 2 COMMUNICATION Communication: Key Function/Comments --- ----------------------------------------------------------------------- A Auto answerback, 0 = Off, 1 = On B Buffer control, 0 = Small, 1 = Large C Printer character set, 1 = United States, 2 = United Kingdom D Auto disconnect, 0 = Off, 1 = On E Local echo, 0 = Off, 1 = On J Auto new line at right margins, 0 = Off, 1 = On L Auto line feed (Return key), 0 = Off, 1 = On N Keyboard/printer character set 1 = United States 2 = United Kingdom O (letter) Alternate character set 0 = OFF 1 = ON U Break enabled 0 = No 1 = Yes W Printer new line character 1 = None 2 = Line feed (LF) 3 = Return (CR) X XON/XOFF 0 = No 1 = Yes Y Alternate keypad mode 0 = No 1 = Yes 2 PARITY Parity and data bits: Key Function/Comments --- ----------------------------------------------------------------------- P Parity and data bits Data Parity Display Bits Rec Xmt ------- ---- ------- ------- 1 7 Ignore Mark 2 7 Ignore Space 3 7 Ignore Odd 4 7 Ignore Even 5 7 Odd Odd 6 7 Even Even 7 7 None None 8 8 None None 9 8 Odd Odd 10 8 Even Even 2 BAUD Select BAUD rate: Key Function/Comments --- ----------------------------------------------------------------------- 0 (zero) Selects receive and transmit baud rates and number of stop bits. Baud Rate Baud Rate (Displayed) Stop Bits (Displayed) Stop Bits ----------- --------- ----------- --------- 50 2 600 1 75 2 1200 1 110 2 1800 1 134 1 2400 1 150 1 4800 1 200 1 7200 1 300 1 9600 1 2 SPLIT Select split BAUD rate: Key Function/Comments ------- ---------------------------------------------------------------- SHIFT 0 Selects split baud rates: 0 selects receive baud rate, SHIFT and 0 then offers a choice of three transmit baud rates. Receive Transmit Baud Rate Baud Rate Transmit (Not Displayed) (Displayed) Stop Bits --------------- ----------- --------- 600 75 2 150 1 600 1 1200 75 2 150 1 1200 1 2400 300 1 600 1 2400 1 4800 300 1 600 1 4800 1 2 MODEM Modem control: Key Function/Comments --- ----------------------------------------------------------------------- M Modem 1 = FDX, No Modem 2 = FDX, Modem 3 = HDX, Supervisory 4 = HDX, EOT 5 = HDX, ETX Q HDX initial call state, 0 = Transmit 1 = Receive S Secondary channel FDX* HDX* Display Mode Rev.Ch. ------- --------- ------- 0 Speed No 1 Restraint Yes *See M Key, Modem 2 STORE #RECALL 2 STATUS #STATUS 2 RECALL Store, Recall and Status: KEY Function/Comments --- ----------------- I Select factory set-up parameters 8 Print status message 9 Recall set-up parameters SHIFT 9 Store set-up parameters 2 TEST Self Test KEY Function/Comments --- ----------------- T Initiate printing self test SHIFT > Initiate non-printing self test NOTE: Type any character in set-up mode to stop self test.